- PRGF - ENDORET®
- Medical specialties
- BTI APNIA®
- Diagnosis
- Treatment

The BTI APNIA® electronic device is a respiratory polygraph designed to simplify the diagnosis of Obstructive Sleep Apnoea (OSA) and snoring disorders. Thanks to its compact size and intuitive handling, it enables home sleep studies with maximum medical reliability and without altering the patient’s sleeping habits.

7 information channels
The true technological milestone of the BTI APNIA® device lies in its ability to provide a highly accurate sleep study while minimising patient discomfort to the greatest extent possible. Unlike complex traditional systems filled with wires and uncomfortable bands, this system simplifies the experience to the maximum: it requires only two intuitively placed external sensors to continuously monitor 7 information channels.
Through a nasal cannula, the device records respiratory airflow. In parallel, a finger pulse oximeter monitors changes in heart rate and blood oxygen levels, accurately capturing any oxygen drop resulting from an apnoea event, while also recording the pulse plethysmography signal.
This external information is intelligently integrated with the internal sensors housed within the device itself, which the patient wears on the chest, and which measure snoring intensity, thoracic respiratory effort, and body position during sleep.
The BTI APNIA® device is designed to support both specialist and patient throughout the therapeutic process, becoming a dynamic, evolving monitoring system. Beyond its initial role in the accurate diagnosis of obstructive sleep apnoea and snoring disorders, this respiratory polygraph is an essential tool for monitoring and titration across different treatment modalities.
Once the patient begins therapy, whether with the APNIA® Intraoral Device (AID), a CPAP machine, or following surgery, the polygraph enables follow-up home studies to be performed in complete comfort. These successive tests are critical for verifying treatment efficacy under real sleep conditions. In addition, in the specific case of intraoral devices such as the AID, it facilitates the titration process, allowing the specialist to adjust the millimetres of splint advancement objectively, based on the progressive, verified reduction in apnoea indices and oxygen desaturations. In this way, BTI APNIA® ensures rigorous, personalised medical follow-up with maximum long-term clinical safety.

Its ergonomic design minimises patient discomfort during the sleep study, ensuring a comfortable and minimally invasive experience.
Its operation and handling have been streamlined to make it highly intuitive and easy to use. The device features a rapid on/off system operated via a single button and status indicator lights, allowing uncomplicated sleep recording in the patient’s own home.
The device can accurately capture 7 different channels of information that are critical for diagnosis: respiratory airflow, ventilatory effort, oximetry, heart rate, body position, snoring and respiratory rate.
APNIA-STUDIES includes a pulse oximeter and a nasal cannula which, together with the internal sensors of the BTI APNIA® device, enable data to be collected comfortably for the patient over a single night.
Fresado simplificado, usando fresas más estrechas y logrando buena estabilidad.
Texto de ejemplo
Guía rápida
Este manual muestra el paso a paso en el sencillo proceso de instalación del dispositivo.
BTI Channel
Webinar de casos clínicos de Apnea del Sueño con la experta Gabriela Zubimendi.
Formación
Guía audiovisual para manejar el sistema de poligrafía BTI APNIA® de forma correcta.
The BTI APNIA® device records 7 key information channels during the night: respiratory airflow, oximetry, heart and respiratory rate, snoring, body position, and a pulse plethysmography channel.
Yes. One of the greatest challenges in home polygraphy is patient rejection or poor sleep quality due to equipment discomfort. The BTI APNIA® device optimises the patient experience by requiring only two external sensors (nasal cannula and pulse oximeter). This removes the need for complex cable networks or additional thoracoabdominal bands, drastically reducing the risk of sleepless nights or failed recordings due to disconnection, and ensuring biological data capture under real, physiological sleep conditions.
Yes. BTI has a robust quality management system based on ISO 13485.
Products manufactured by BTI comply with Medical Device Directive 93/42/EEC and Medical Device Regulation 2017/745. Conformity has been assessed and certified by the Notified Body TÜV SÜD (no. 0123), supporting their safety, efficacy, and reliability worldwide.
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
¡Gracias!