Pathology: Horizontal atrophy

Use of 2.5 mm diameter implants for the rehabilitation of sectors with horizontal bone atrophy, avoiding the need for prior regenerative procedures.

Implants with a diameter of 2.5 mm are a versatile and effective solution for restoring extensive edentulous spans or complete arches without resorting to complex grafting procedures. In this case, they were placed directly, allowing almost complete restoration of the maxilla alongside two narrow distal implants. Read more
View clinical case

Pathology: Horizontal atrophy

Rehabilitation of maxillary and mandibular horizontal atrophies using 3.0 mm narrow platform implants: a minimally invasive approach.

Narrow-diameter implants with a 3.0 mm platform offer a predictable solution for treating severe horizontal atrophy, both in single-tooth sites and in full-arch restorations, establishing a minimally invasive protocol that avoids complex regenerative techniques. In this case, they were used as part of the maxillary restoration in the anterior sector and in both posterior mandibular sectors. Read more
View clinical case

Pathology: Vertical atrophy

Rehabilitation of a maxilla with extreme vertical atrophy using almost exclusively 4.5 mm long implants.

Implants measuring 4.5 mm in length offer a predictable, minimally invasive solution for vertical atrophy of the maxilla and mandible. They can be used alone or in combination with transcrestal elevation, nasal fossa approaches or vertical bone regeneration. In this patient, they supported almost the entire maxillary restoration, being splinted to two distal implants measuring 5.5 mm. Read more
View clinical case

Pathology: Vertical atrophy

4.5 mm extra-short implants for the treatment of severe bone atrophy in the posterior maxilla: an alternative to conventional bone regeneration and sinus elevation techniques.

Posterior maxillary atrophy has traditionally been managed with sinus elevation (lateral or transcrestal). However, the transcrestal approach has classically required 4–5 mm of residual bone height to ensure primary stability. Implants measuring 4.5 mm overcome this limitation by achieving predictable three-dimensional anchorage in severely atrophic ridges, avoiding more invasive techniques, as in the case presented. Read more
View clinical case

Pathology: Vertical atrophy

Vertical bone augmentation in the posterior mandible with distal free ends to avoid prosthetic cantilevers in full-arch implant-supported rehabilitations.

Vertical atrophy in the posterior mandible has traditionally been treated with block grafts, guided bone regeneration or transposition of the inferior dental nerve. Vertical bone growth simplifies this approach by using the implant itself as a scaffold for bone growth: the implant is positioned slightly supracrestally, and the defect is regenerated using only autologous bone collected during drilling, combined with PRGF-Endoret®, as demonstrated in this case, where this approach enabled a prosthesis without distal cantilevers. Read more